For Customer UseEnter below the Serial No.which is located on thebottom of the cabinet. Retainthis information for future ref-erence.Model No.: IK-TF7
102MANU (Manual white balance)• Set the MODE to MANU on the WHT BAL menu.(Refer to the item "7.2 (3) WHT BAL (white balance)".)• Shoot a kno
117. MODE SETTING BY ON SCREEN DISPLAYVarious settings can be controlled on the unit by using the on screen menu displayed on the monitor. Thecontents
127. 2 Menus• Select the menu to change the setting by referring the item "7.1 Using the Menus".)• When the [MENU UP], [MENU DOWN] buttons a
13(1. 2) Changing each setting in SS (synchro. scan) mode(a) Changing the shutter speed setting1Set the "→" to SS by pushing [MENU UP], [MEN
14(1. 3) Changing each setting in E.TRG modeThe E.TRG has five modes; 1P SNR, 1P SR, PW SNR, PW SR, RR.First set the "→" to MODE and select
15(1. 3. 2) Changing each setting in 1P SR mode(a) Changing the polarity of inputting trigger pulse setting1Set the "→" to TRG.P by pushing
16(1. 3. 3) Changing each setting in PW SNR mode(a) Changing the polarity of inputting trigger pulse setting1Set the "→" to TRG.P by pushing
17(1. 3. 4) Changing each setting in PW SR mode-- SHUTTER --MODE E.TRGE.TRG PW SRTRG.PPART OFF<MODE = E.TRG E.TRG = PW SR>• Partial scanning s
18(1. 3. 5) Changing each setting in RR mode(a) Changing the partial scanning setting1Set the "→" to PART by pushing [MENU UP], [MENU DOWN]
19( 3 ) WHT BAL (White balance)WHT BAL has two modes; AWB, MANU.Set the "→" to MODE, push the [DATA UP], [DATA DOWN], and select mode amon
2SAFETY PRECAUTIONSSafety iconsThis manual contains safety instructions that must be observed in order to avoid potentialhazards that could result in
20( 4 ) PROCESS(4. 1) Changing master pedestal1Set the "→" to M. PED by pushing [MENU UP], [MENU DOWN] buttons.2Set the master pedestal by
21( 5 ) SYNCWhen an external sync signal is input, the display menu changes from INT (internal sync) to EXT (externalsync) automatically.(5. 1) Adju
227. 3 External SyncWhen using the unit with an external sync signal, input HD and VD to CC3 and CC4 of the DIGITAL terminal.When the external sync si
23( 3 ) Using the unit with external sync signalWhen adjusting H (horizontal) phase refer to the item "7.2 (5) (5.1) Adjusting horizontal phase
247. 5 EXT TRIG (External trigger)Charge begins to accumulate after the trigger input to CC1 of the DIGITAL terminal, and 1 frame images areoutput. T
25About 1 µsExposure period*2Exposure period*2Trigger*1Negative polarity modePositive polarity modeRGB data (video interval image)(Internal VD)*3FVALL
26( 2 ) 1P SR (1 Pulse Trigger Sync Reset)Charge begins to accumulate after the trigger input to CC1 of the DIGITAL terminal, the vertical sync sign
27( 3 ) PW SNR (Pulse width trigger SYNC-NON RESET)The trigger input to CC1 of the DIGITAL terminal develops 1 frame images.(3. 1) Pulse Width Trigg
28(3. 2) Pulse Width Trigger SYNC-NON RESET Picture Output Timing (at Time of Internal Sync)*1: Externally input signal*2: Exposure time = Trigger pul
29( 4 ) PW SR (Pulse width trigger SYNC-RESET)The trigger input to CC1 of the DIGITAL terminal develops 1 frame images.(4. 1) 1 Pulse Width Trigger
3DisclaimerWe disclaim any responsibility and shall be held harmless for any damages or losses incurred by theuser in any of the following cases:1. Fi
30( 5 ) RR (Reset restart)Input of an external reset-restart signal (CC4 of the DIGITAL terminal: External VD input) permits one screenof informatio
317. 6 Partial Scanning1/29.2s (796H)Video interval imageBlanking intervalBBlanking intervalDTotalAVideo intervalCRGB data (video interval image)(Inte
328. INPUT OUTPUT SIGNAL SPECIFICATOINS2.0 µs to 5.0 µs (Positive polarity mode) (Negative polarity mode)More than 2 µsMore than 2 µs5H to 21H( 6 ) E
339. CCD OUTPUT WAVEFORM TIMING CHART( 1 ) Horizontal Output Waveform Timing Chart246 clk40 clkCLK=33.9 nsec(29.5 MHz)164 clk29 clk3 clk5 clk33.9 nsLV
3410. SPECIFICATIONSPower supplyPower consumptionPick-up systemImage sensor(Effective pixels)Scanning systemScan frequencySync systemHorizontal resolu
3512. BEFORE MAKING A SERVICE CALLSymptomNo imagePoor colorItems to be checked• Is the power supplied correctly?• Is the lens iris adjusted correctly?
LIMITED WARRANTYTOSHIBA CCD CAMERAPromptly register your product with Toshiba on-line at www.toshiba.com/taisisd. By registering your prod-uct you wil
41. CAUTIONS ON USE AND INSTALLATION ... 52. COMPONENTS ... 53. ITEMS CONTROLLED BY USINGON SCREEN DISP
51. CAUTIONS ON USE AND INSTALLATION•Carefully handle the units.Do not drop, or give a strong shock or vibration tothe camera. This may cause problems
63. ITEMS CONTROLLED BY USING ON SCREEN DISPLAYMODEE. TRGMANU speedSyncro.scan.Partial scanningTrigger (1P SNR/SR)Trigger(PW SNR/SR)1Pexposure timeMOD
74. NAMES AND FUNCTIONSDISPPAGEDC IN 12VMENUDATA(AWB)182467593Prism faceplateDIGITAL terminalDISP buttonPAGE button[ Rear ][ Front ]MENU UP buttonMENU
85. CONNECTION5. 1 Standard Connection5. 2 Cautions on Connection• When connecting the camera cables, unplug the power source of the camera and the ot
96. OPERATION1Refer to the item " 5. CONNECTION", connect each equipment correctly.2Turn on the connected equipment and the power source of