Toshiba ETB004Z Manuel d'utilisateur Page 9

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 18
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 8
E6581341
8
2.2. Wiring
When conducting wiring, follow the instructions below.
Use shield wire for control signal line and ground the unit with shield wire
(Use twisted pair shield cable for wiring of the analog monitor output.
)
Never bind the signal line and main circuit connection wire together
.
Fix the communication cables after connected.
Terminal Block Applicable wire size
The wire length of
peel off the end
Using screwdriver
(The blade tip)
Tightening
torque
TB1 0.2 to 2.5 mm
2
About 7mm
0.6mm thickness
and 3.5mm width.
0.5 to 0.6 N󲦷m
TB2 to TB4 0.2 to 1.5mm
2
About 5mm
0.4mm thickness
and 2.5mm width.
0.22 to 0.25 N󲦷m
< Input/output terminal interface >
Terminal
symbol
Function Electrical specification Internal circuit
R2A
R2B
R2C
Relay contact
point output
Configuration of 1C contact point
250Vac - 2A (cosφ=1)
250Vac - 1A (cosφ=0.4)
30Vdc - 1A
R2A
R2B
R2C
Ry
LI5
LI6
LI7
LI8
Contact point
input Changeover
of sink or source
No voltage contact input
24Vdc - 5mA
Sink input(common voltage 24V)
ON less than 10Vdc
OFF 16Vdc or more
Source input
ON 11Vdc or more
OFF less than 5Vdc
Note:
Even when an external power supply
is used (in sink logic mode i.e. when
SINK(PLC) is selected), connect the
reference potential-side (0V side)
cable from the power supply to the CC
terminal.
24V power supply
24Vdc power output (when SW is
in any position other than PLC)
24V internal output terminal
24Vdc - 60mA max
PLC/
P24
Common terminal
for external
power supply
If SW is turned to the PLC position,
this terminal can be used as a
common terminal when an external
power supply is used.
SINK LogicSW=SINK(INT)
SW
2.2k ohm
2.2k ohm
CC
LI5
LI6
LI7
LI8
SOURCE
P24/
PLC
SINK(PLC)
SINK
(INT)
P24
SINK Logic (SW=SINK(PLC))
SW
2.2k ohm
2.2k ohm
CC
LI5
LI6
LI7
LI8
SOURCE
P24/
PLC
SINK(PLC)
SINK
(INT)
P24
SOURCE Logic (SW=SOURCE)
SW
SOURCE
2.2k ohm
P24/
PLC
2.2k ohm
CC
LI5
LI6
LI7
LI8
SINK(PLC)
SINK
(INT)
P24
Lan current signal.
Chose low current contacts to
avoid poor attaching.
Vue de la page 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 17 18

Commentaires sur ces manuels

Pas de commentaire