Toshiba XLTR-200 Manuel d'utilisateur Page 28

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 99
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 27
27
12. Console Access
12.1 RS232
The console is accessible via an RS232 interface for direct connection to a
computer’s serial (COM) port. This is performed by connecting the unit’s
RS232 port to the computer’s serial port via a standard straight-thru serial
cable.
12.1.1 Requirements
All that is needed is a computer with a serial (COM) port containing some sort
of communications software (such as HyperTerminal, included with Microsoft
Windows operating systems) and a straight-thru serial cable, such as the Belkin
6’ serial extension cable (Belkin part #F2N209-06). Refer to Figure 6 for a
representative example cable. Any communications software and PC will work,
provided they support ASCII communications at 38.4kbaud.
Figure 6: A Typical Serial Extension Cable
12.1.2 Connection
Connect one end of the serial cable to the gateway’s RS232 port, and connect
the other end to the computer’s serial port. Make sure that CFG DIP switch #2
is in the “OFF” (left) position to force the RS232 port to act as the serial
console. If the unit is currently using the RS232 port for control protocol
communication, then it must be rebooted (powered down and then back up
again) with CFG switch #2 in the OFF position to enable the serial console on
the RS232 port.
Vue de la page 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 98 99

Commentaires sur ces manuels

Pas de commentaire