Toshiba E-STUDIO900 Manuel d'utilisateur Page 35

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 224
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 34
PTM 2-10 B070/B071
Original Exit (Single-Sided Original Mode)
The exit gate solenoid [A] remains off, the exit gate [B] remains closed, and the
original is fed out to the right exit tray.
The speed of the motor is reduced about 30 mm from the trailing edge of the original
to ensure the originals stack neatly on the exit tray. This timing is determined by the
length of the original, and the time since the exit sensor [C] detected the leading edge.
The transport belt motor turns off after the exit sensor [C] turns off.
B070D928.WMF
[C]
[A]
[B]
Vue de la page 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 223 224

Commentaires sur ces manuels

Pas de commentaire